Protection for people
A safe path for the current keeps people inside and around the building safer.
Kerala sees heavy thunderstorms every year, and one strike can damage wiring, inverters, TVs and even put lives at risk. String Solar designs, installs and tests every lightning arrest system, from the first roof visit to the final earth test, so your property stays protected without the guesswork.
A lightning arrest system, also called a lightning protection system, is a set of rods, conductors and earthing that catches a lightning strike and carries its current safely into the ground. Instead of travelling through your walls and wiring, the strike follows the path we build for it.
It does not attract more lightning or stop it from happening. It controls where the energy goes. Add surge protection devices inside the building, and your electrical equipment is shielded from the surge that travels along cables.

From the first site assessment to clean energy, every step is designed to make your solar journey simpler.
A safe path for the current keeps people inside and around the building safer.
Cuts the risk of fire, cracked walls and burnt wiring caused by a strike.
Surge protection guards inverters, panels, TVs, routers and appliances.
Shops, offices and factories avoid long breaks caused by damaged equipment.
There are no moving parts. A yearly check and earth test are usually enough.
Planned around IS/IEC 62305, the standard for lightning protection.
Not sure which type of air terminal suits your building? This quick comparison should help.
| Feature | Conventional Rod | Mesh (Cage) | ESE Terminal |
|---|---|---|---|
| How it works | Rod fixed at the highest point | Network of conductors over the roof | Single terminal claiming an earlier response |
| Best for | Houses, shops and small buildings | Large flat roofs and sensitive equipment | Open areas, as advised case by case |
| Cost | Lowest of the three | Higher, as more material is used | Medium |
| IS/IEC 62305 | Covered | Covered | Not covered |
No lightning arrest system can promise 100% protection, and none can stop lightning from striking. It gives the strike a safe route and greatly reduces damage, but a direct strike can still cause some effects. An arrestor is only as good as its earthing. Dry soil, loose joints and corrosion raise the resistance over time, which is why we test the earthing and recommend a yearly check.
Rod or terminal at the top that receives the strike
Copper or GI conductor that carries the current to the ground
Low‑resistance earthing that spreads the current into the soil
Tight, corrosion‑resistant joints so the whole path stays continuous
Shield your panel and electronics from surges on the wiring
Terminals and bonding for rooftop plants

Our system is suitable for a wide range of properties.
Proven solar engineering across Kerala.
Certified, credible and compliant standards.
Survey, design, supply, installation and service.
Backed by fast on‑site repair and maintenance.
Headquartered in Calicut, prompt whenever you call.
Trusted by 1,000+ households & businesses across Kozhikode & Kerala.
The price depends on your building height and size, the type of air terminal, the number of down conductors and earth pits, the soil, and whether surge protection is added. Rather than quote a random number, we assess your building and give you an itemised quote with no hidden charges.
Here’s a straightforward way to think about it. A small house usually needs one air terminal, one or two down conductors and one or two earth pits. A large roof or factory needs several of each, spread out so the whole building is covered. Your actual design depends on the roof layout and soil, and our engineer will confirm it during the survey.
The number of terminals, conductors and earth pits depends on the property. These are indicative set‑ups, and the survey gives the final design.
| System Size | Central Subsidy | Good to Know |
|---|---|---|
| Small house or shop | 1 air terminal, 1 to 2 down conductors, 1 to 2 earth pits | Suits a modest roof area |
| Large building or factory | Several terminals or roof mesh, more conductors and earth pits | Count follows the risk check |
| Rooftop solar plant | Terminals above the array, bonded earthing, surge protection | Designed along with the plant |

Free Site Survey
Kozhikode & All Kerala
We are based in Kozhikode (Calicut) and install lightning arrest systems for homes, shops, offices, factories and institutions across Kerala.
Together, let’s look at your building and its risk. You will get honest advice, a clear quote and a system built to last.